Dynon Avionics SkyView System Installation Guide User Manual

Page 315

Advertising
background image

SV-COM-X83 Installation, Configuration, and Testing

SkyView System Installation Guide – Revision S

17-13

On the SV-COM-T8 #1 end, continue the shield as far into the connector as possible until

you're forced to pare it back to access the two inner wires. Put some heat shrink tubing
over the shield to keep it electrically isolated - the shield at the SV-COM-T8 #1 end of
this cable is not electrically connected at SV-COM-T8 #1.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

Shielded cable between SV-COM-T8 #1 Pins 23 and 9, and SV-INTERCOM-2S Pins 1 and 25:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-T8 #1 Pin 23 to SV-INTERCOM-2S Pin 25.

Use the other wire to connect SV-COM-T8 #1 Pin 9 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-T8 #1 end, continue the shield as far into the connector as possible until

you're forced to pare it back to access the two inner wires. Put some heat shrink tubing
over the shield to keep it electrically isolated - the shield at the SV-COM-T8 end of this
cable is not electrically connected at SV-COM-T8 #1.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

Shielded cable between SV-COM-T8 #2 Pins 1 and 2, and SV-INTERCOM-2S Pins 1 and 7:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-T8 #2 Pin 2 to SV-INTERCOM-2S Pin 7.

Use the other wire to connect SV-COM-T8 #2 Pin 1 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-T8 #2 end, continue the shield as far into the connector as possible until

you're forced to pare it back to access the two inner wires. Put some heat shrink tubing
over the shield to keep it electrically isolated - the shield at the SV-COM-T8 #2 end of
this cable is not electrically connected at SV-COM-T8 #2.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

Shielded cable between SV-COM-T8 #2 Pins 23 and 9, and SV-INTERCOM-2S Pins 1 and 15:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-T8 #2 Pin 23 to SV-INTERCOM-2S Pin 15.

Use the other wire to connect SV-COM-T8 #2 Pin 9 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-T8 #2 end, continue the shield as far into the connector as possible until

you're forced to pare it back to access the two inner wires. Put some heat shrink tubing
over the shield to keep it electrically isolated - the shield at the SV-COM-T8 end of this
cable is not electrically connected at SV-COM-T8 #2.