SV-EMS-220/221 Installation and Configuration

7-12

SkyView System Installation Guide - Revision S

installations that differ significantly from these standard installations should be designed to not
exceed the following current limitations:

EMS

Module

Output

Pin

Output

Current

Limit

Wire Color

Current Draw of Sensors that Use This Output

12V

15

80mA

Red

FloScan Fuel Flow Sensor (100403-001): 50mA
EI Fuel Flow Sensor (100403-003): 15mA
UMA Differential Fuel Pressure: 10mA
Rotax Honeywell Oil Pressure Sensor: 20mA
Rotax Oil Pressure Sensor

P/N 456180: 20mA

Dynon Capacitance to Voltage Converter: 25mA

5V

18

300mA

(Limited

by

internal

self-

resetting

fuse)

White/Red



Kavlico pressure sensors: 5mA
3

rd

party trim and flaps position: 5mA

Manifold pressure sensor (100434-000): 10mA

Table 17 – EMS Module Current Draw Limits for 5/12V Lines

Example Engine Sensor and Transducer Installations

This section contains example engine sensor and transducer installations for popular engines.
Each engine subsection listed on the following pages contains tables for each SV-EMS-220/221
connector and suggests a way to connect that engine’s required sensors to the EMS module.
These tables are based on the downloadable mapping and settings files available from Dynon’s
support forums and may need to be modified based on your particular installation.