Appendix C: Wiring and Electrical Connections

22-16

SkyView System Installation Guide - Revision S

15

11-33V DC

Connect to Aircraft Power

16

No Connect

-

17

External Standby

In

Optional: Not Commonly Connected

18

Mutual

Suppression

Optional: Not Commonly Connected

19

Squat Switch In

Optional: Not Commonly Connected

20

Ident Switch In

Optional: Not Commonly Connected

21

No Connect

-

22

No Connect

-

23

No Connect

-

24

No Connect

-

25

No Connect

-

Table 82 – SV-SPNDR-26X D25 Connector

SV-XPNDR-261/262 Environmental Qualification Forms

Nomenclature:

TT21 Mode S Transponder (Dynon Avionics SV-XPNDR-262)

Part Number: 00675-(XX)

ETSO: 2C112b, C166a

Manufacturer:

Trig Avionics Limited

Address:

Heriot Watt Research Park, Riccarton, Currie, Scotland, EH14 4AP

Conditions

DO-160F

Section

Description of Conducted Tests

Temperature and Altitude

4.0

Equipment tested to Categories A2, C1

Low temperature ground survival

4.5.1

-55°C

Low temperature short-time
operating

4.5.1

-40°C

Low temperature operating

4.5.2

-20°C

High temperature operating

4.5.4

+70°C

High temperature short-time
operating

4.5.3

+70°C

High temperature ground survival

4.5.3

+85°C

Loss of Cooling

4.5.5

Cooling air not required (+70°C operating without cooling air)

Altitude

4.6.1

35,000 feet

Decompression

4.6.2

8,000 to 35,000 feet in 15 seconds

Overpressure

4.6.3

-15,000 feet

Temperature Variation

5.0

Equipment tested to Category C

Humidity

6.0

Equipment tested to Category A

Operational Shocks

7.2

Equipment tested to Category B

Crash Safety

7.3

Equipment tested to Category B type 5

Vibration

8.0

Aircraft zone 2; type 3, 4, 5 to category S level M, type 1 (Helicopters) to
category U level G