Dynon Avionics SkyView System Installation Guide User Manual

Page 305

Advertising
background image

SV-COM-X83 Installation, Configuration, and Testing

SkyView System Installation Guide – Revision S

17-3

Physical Installation

SV-COM-PANEL – VERTICAL Installation Dimension Quick Overview

Panel Cutout: (irregular – see drawing)

Bezel Outline: 1.80” W x 3.532” T (45.72 mm W x 89.71 mm T)

Note that the SV-COM-PANEL/V is sized such that two units can be stacked to
the same height as the height of an SV-D1000 display.

SV-COM-PANEL - HORIZONTAL Installation Dimension Quick Overview

Panel Cutout: (irregular – see drawing)

Bezel Outline: 3.532” W x 1.80” T (89.71 mm W x 45.72 mm T)

To mount an SV-COM-PANEL, cut the opening in your panel, drill out the mounting holes, install
nutplates, and use the included mounting screws to fasten the display to the panel.

Your SV-COM-X83 is shipped with #6-32 hex-drive round head fasteners. Fasteners are 5/8”
long and require a 5/64” hex drive tool. Dynon recommends fastening the included mounting
screws to nut plates installed behind the panel. If access behind the panel allows, standard #6-
32 lock nuts or nuts with lock washers can be used. Do not rivet the SV-COM-PANEL to the panel
as this will hinder future removal if necessary.

Mounting Dimensions

The following diagrams are NOT to scale. However, paper templates are included
with your SV-COM-C25 and may also be downloaded from

http://docs.dynonavionics.com

.