System Planning

SkyView System Installation Guide – Revision S

2-3

Table 3 contains power specifications for SkyView modules that are powered from ship’s power
(not powered by SkyView Network). A 5A circuit breaker is recommend in most cases because
that is the smallest circuit breaker that is commonly available in certified versions.

Unit

Current

requirement

@ 12 volt DC

Current

requirement

@ 24V DC

Circuit

Breaker

Recommendation

SV-ADSB-470

0.2A maximum

0.1A maximum

5A

SV-AP-PANEL

(Trim motor control section)

4.0A maximum

(depends on the trim

motors used)

Not Applicable

5A

SV-COM-C25

3.0A maximum

(transmitting)

1.5A maximum

(transmitting)

5A

SV-COM-X83

2.0A maximum

(transmitting)

1.0A maximum

(transmitting)

5A

SV-XPNDR-261/262

0.4A maximum

0.2A maximum

5A

SV32/SV32C/SV32L

1.3A maximum

(moving 100% torque)

0.7A maximum

(moving 100%

torque)

5A

SV42/SV42C/SV42EL/SV42L/SV42T

2.0A maximum

(moving 100% torque)

1.0A maximum

(moving 100%

torque)

5A

SV52/SV52C/SV52L

2.8A maximum

(moving 100% torque)

1.4A maximum

(moving 100%

torque)

5A

Heated AOA / Pitot Probe

10A (maximum heat)

Not Applicable

10A

Serial to Gray Code Converter

Module

0.01 A (10 mA)

0.05 A (50 mA)

5A

(or add to another fuse or

circuit breaker)

Table 3 – SkyView Modules Power Specifications