SV-COM-C25 Installation, Configuration, and Testing

SkyView System Installation Guide – Revision S

16-9

Note that SkyView Network connection(s) on SV-COM-PANEL are not shown, nor are additional
connections between the SV-INTERCOM-2S and other devices that it connects to.

Figure 101 – Single SV-COM-C25 to SV-INTERCOM-2S

Single SV-COM-C25 to SV-INTERCOM-2S Harness Construction Notes

Shielded cable between SV-COM-425 Pins 9 and 10, and SV-INTERCOM-2S Pins 1 and 14:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-425 Pin 10 to SV-INTERCOM-2S Pin 14.

Use the other wire to connect SV-COM-425 Pin 9 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-425 end, continue the shield as far into the connector as possible until

you're forced to pare it back to access the two inner wires. Put some heat shrink tubing
over the shield to keep it electrically isolated - the shield at the SV-COM-425 end of this
cable is not electrically connected at the SV-COM-425.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see below).

Advertising