SV-COM-C25 Installation, Configuration, and Testing

16-12

SkyView System Installation Guide - Revision S

Shielded cable between SV-COM-425 #1 Pins 1 and 2, and SV-INTERCOM-2S Pins 1 and 25:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-425 #1 Pin 1 to SV-INTERCOM-2S Pin 25.

Use the other wire to connect SV-COM-425 #1 Pin 2 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-425 #1 end, continue the shield as far into the connector as possible

until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-425 end
of this cable is not electrically connected at SV-COM-425 #1.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

Shielded cable between SV-COM-425 #2 Pins 9 and 10, and SV-INTERCOM-2S Pins 1 and 7:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-425 #2 Pin 10 to SV-INTERCOM-2S Pin 7.

Use the other wire to connect SV-COM-425 #2 Pin 9 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-425 #2 end, continue the shield as far into the connector as possible

until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-425 #2
end of this cable is not electrically connected at SV-COM-425 #2.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

Shielded cable between SV-COM-425 #2 Pins 1 and 2, and SV-INTERCOM-2S Pins 1 and 15:

This cable consists of two wires plus shield.

Use one of the wires to connect SV-COM-425 #2 Pin 1 to SV-INTERCOM-2S Pin 15.

Use the other wire to connect SV-COM-425 #2 Pin 2 to SV-INTERCOM-2S Pin 1 (see

instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

On the SV-COM-425 #2 end, continue the shield as far into the connector as possible

until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-425 end
of this cable is not electrically connected at SV-COM-425 #2.

On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it

(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).

Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S

Eight connections terminate into SV-INTERCOM-2S Pin 1:

o SV-COM-425 #1 Pin 9
o Shield of the cable from SV-COM-425 #1 Pins 9 and 10
o SV-COM-425 #1 Pin 2

Advertising