SV-COM-C25 Installation, Configuration, and Testing

16-14

SkyView System Installation Guide - Revision S

Figure 104 – Headset Jack Schematic Interpretation

Power/Ground Input

The SV-COM-C25 requires 10-30V DC. For wire runs from power distribution to the SV-COM-
425 up to 6’, 22 AWG wire is sufficient for power and ground wires. For wire runs from power
distribution to the SV-COM-425 longer than 6’, 20 AWG wire is recommended for power and
ground wires. For the cable between the SV-COM-425 and the SV-COM-PANEL, 22 AWG power
and ground wire is sufficient. Use a 5 Amp fuse or circuit breaker for power supply protection to
each SV-COM-C25.

Power Specifications

Approximate current

consumption at 12 volts DC

Approximate current

consumption at 24 volts DC

SV-COM-C25 – Transmit

3.0 amps average

1.5 amps average

SV-COM-C25 – Receive

0.2 amps average

0.1 amps

Table 58 – SV-COM-C25 Power Consumption