Figure 95, Serial port setup–dynon converter format – Dynon Avionics SkyView System Installation Guide User Manual

Page 277

Advertising
background image

Accessory Installation and Configuration

SkyView System Installation Guide – Revision S

15-7

TX

GND

Green Wire

Black Wire

SkyView Display Serial Transmit

Shared Ground

Encoder Converter

Module

SkyView Display

DB37 Connector

A1
A2
A4
B1
B2
B4
C1
C2
C4
D4
Strobe

Yellow
Green
White/Blue
Blue
Orange
White/Red
White/Green
White
White/Black

Unconnected
Unconnected

Transponder

Red

Black

10-30 volts

Ground

The Encoder Converter Module

is compatible with all SkyView

display serial ports.

Figure 95 – Encoder Converter Module Electrical Connections

Serial Port Setup–DYNON CONVERTER Format

Enter the Serial Port Setup Menu (SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP) on
each display and configure the appropriate serial port for use with the Encoder Serial-to-Gray
Code Converter module with the following settings:

SERIAL # IN DEVICE:

NONE

SERIAL # IN FUNCTION:

NONE

SERIAL # IN/OUT BAUD RATE:

1200

SERIAL # OUT DEVICE:

DYNON CONVERTER

Advertising