Pin

Rotax 912

Harness

(except 912 iS)

(100399-004)

4-cyl Harness
(100399-001)

6-cyl Harness
(100399-002)

Wire

Color

Function

Sensor Config

1

Do not connect

2

Red

CHT 6

J thermocouple

3

Red

EGT 6

K thermocouple

4

Red

CHT 5

J thermocouple

5

Red

EGT 5

K thermocouple

6

Red

CHT 4

J thermocouple

7

Red

EGT 4

K thermocouple

8

Red

CHT 3

J thermocouple

9

Red

EGT 3

K thermocouple

10

Red

CHT 2

J thermocouple

11

Red

EGT 2

K thermocouple

12

Red

CHT 1

J thermocouple

13

Red

EGT 1

K thermocouple

14

White

CHT 6

J thermocouple

15

Yellow

EGT 6

K thermocouple

16

White

CHT 5

J thermocouple

17

Yellow

EGT 5

K thermocouple

18

White

CHT 4

J thermocouple

19

Yellow

EGT 4

K thermocouple

20

White

CHT 3

J thermocouple

21

Yellow

EGT 3

K thermocouple

22

White

CHT 2

J thermocouple

23

Yellow

EGT 2

K thermocouple

24

White

CHT 1

J thermocouple

25

Yellow

EGT 1

K thermocouple

Table 16 – SV-EMS-220/221 Female D25 Pin-to-Sensor Compatibility

The Rotax harness only has EGTs 1 and 2 wired, as the EMS measures the Rotax-supplied
resistive CHTs through its GP inputs. The four-cylinder harness only has EGTs 1 through 4 and
CHTs 1 through 4 wired. On the supplied harness, each pair of wires is encased in brown
insulation and labeled with corresponding cylinder number. Inside the outer insulations, each
wire in the pair has the color listed in Table 16 and Figure 30.

If you make a custom thermocouple harness, note that all differential
thermocouple inputs on the D25 and the D37 (SV-EMS-220 only) connectors are
compatible with both J and K type thermocouples. Note that you will need to

Advertising