Dynon Avionics SkyView System Installation Guide User Manual

Page 144

Advertising
background image

SV-EMS-220/221 Installation and Configuration

7-32

SkyView System Installation Guide - Revision S

SECONDARY EMS MODULE with 100399-001 Harness

Pin

EMS 25-pin Thermocouple

Harness Wire Color

Sensor (with Dynon part number if

applicable)

1

Open

N/A

2

Red

Harness does not have a wire in this pin

3

Red

Harness does not have a wire in this pin

4

Red

Harness does not have a wire in this pin

5

Red

Harness does not have a wire in this pin

6

Red

Not Connected (Harness label CHT 4)

7

Red

Not Connected (Harness label EGT 4)

8

Red

CHT 9 (Harness label CHT 3)

(J-type thermocouple, 100404-000*)

9

Red

EGT 9 (Harness label EGT 3)

(K-type thermocouple, 100405-000*)

10

Red

CHT 8 (Harness label CHT 2)

11

Red

EGT 8 (Harness label EGT 2)

12

Red

CHT 7 (Harness label CHT 1)

13

Red

EGT 7 (Harness label EGT 1)

14

White

Harness does not have a wire in this pin

15

Yellow

Harness does not have a wire in this pin

16

White

Harness does not have a wire in this pin

17

Yellow

Harness does not have a wire in this pin

18

White

Not Connected (Harness label CHT 4)

19

Yellow

Not Connected (Harness label EGT 4)

20

White

CHT 9 (Harness label CHT 3)

21

Yellow

EGT 9 (Harness label EGT 3)

22

White

CHT 8 (Harness label CHT 2)

23

Yellow

EGT 8 (Harness label EGT 2)

24

White

CHT 7 (Harness label CHT 1)

25

Yellow

EGT 7 (Harness label EGT 1)

Table 35 – Example 9-cylinder Radial Primary SV-EMS-220 25-pin Connector Sensor Map

* Note that J-type and K-type thermocouples apply to all CHTs or EGTs, respectively. They are
not repeated in the table for brevity’s sake.

In Table 34 above, the Primary SV-EMS-220 uses a 100399-002 6-cylinder CHT/EGT harness;
these are connected to Cylinders 1-6.

In Table 35 above, the Secondary SV-EMS-220 uses a 100399-001 4-cylinder CHT/EGT harness;
cables marked Cylinders 1-3 are connected to Cylinders 7-9, respectively.

To configure dual EMS’ to support additional thermocouples (CHTs / EGTs), go to
SV-EMS-220, SETUP MENU > EMS SETUP > DUAL EMS SETUP:

Advertising