Example Oil Temperature Sensor Setup

Assume this sensor was mapped on the Sensor Input Mapping Wizard as:

PIN #

FUNCTION

SENSOR

NAME

C37 P7

TEMPERATURE

5/8”-18 NPT FLUID TEMP (100409-000)

OIL

Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the OIL TEMPERATURE Page (SETUP MENU > EMS SETUP > SENSOR SETUP > OIL
TEMPERATURE).

Configure OIL TEMPERATURE with the following properties:

ALARM:

LATCHING

MAXIMUM GRAPHICAL DISPLAY:

260 °F

MINIMUM GRAPHICAL DISPLAY:

80 °F

SHOW SENSOR UNITS

YES

RANGE 1

o ENABLE

YES

o COLOR

YELLOW

o TOP

165 °F

o BOTTOM

80 °F

RANGE 2

o ENABLE

YES

o COLOR

GREEN

o TOP

220 °F

o BOTTOM

165 °F

RANGE 3

o ENABLE

YES

o COLOR

YELLOW

o TOP

240 °F

o BOTTOM

220 °F

RANGE 4

o ENABLE

YES

o COLOR

RED

o TOP

260 °F

o BOTTOM

240 °F

RANGE 5

o ENABLE

NO

o COLOR

RED

o TOP

5 °F

o BOTTOM

0 °F

Note that oil temperature is configured with a latching alarm in this example. If oil
temperature ever reaches a range configured as red, an alarm will trigger and a