SV-EMS-220/221 Installation and Configuration

7-30

SkyView System Installation Guide - Revision S

Example 9-cylinder Radial (Using Dual SV-EMS-220s,
100399-000, 100399-001, 100399-002 Harnesses)

PRIMARY EMS MODULE with 100399-000 Harness

Pin

EMS 37-pin Harness

Wire Color

Sensor (with Dynon part number if

applicable)

1

Red

Battery Voltage (Voltmeter Input)

2

Yellow or Unwired

Not Connected

3

Black

Ground

4

Violet/Blue

Elevator Position Potentiometer

5

Black

Ground

6

White/Yellow

150 PSI Oil Pressure (101693-000)

7

White/Brown

Oil Temperature (100409-000)

8

Brown

15 PSI Fuel Pressure (101690-000) or

50 PSI Fuel Pressure (101716-000)

9

Brown/Blue

Heated Pitot Status (Contact Input)

10

Brown/Yellow

Not Connected

11

Orange

Not Connected

12

Yellow

Not Connected

13

Black

Ground

14

Yellow

Fuel Flow (100403-003)

15

Red

Fuel Flow Power (100403-003)

16

Black

Ground

17

Black

Ground

18

White/Red

Manifold Pressure Sensor Power (+5 Volt) and

Kavlico Pressure Sensors (+5 Volt)

19

White/Black

Not Connected

20

Orange/Brown

Fuel Level Left (Resistive)

21

Orange/Blue

Fuel Level Right (Resistive)

22

Violet/Yellow

Flaps position Potentiometer

23

Violet/Green

Not Connected

24

Orange/Green

Ammeter Shunt + (100412-000)

25

Orange/Violet

Ammeter Shunt – (100412-000)

26

Green/Red

Manifold Pressure (100434-000)

27

Open

Not Connected

28

Open

Not Connected

29

Yellow/Green

Optional External Alarm Light

30

Black

Not Connected

31

White/Orange

Not Connected

32

White/Green

RPM Left (Standard)

33

White/Blue

RPM Right (Standard)

34

Blue

Not connected

35

Green

Not Connected

36

Blue or Unwired

Not Connected

37

Green or Unwired

Not Connected