Appendix C: Wiring and Electrical Connections

22-12

SkyView System Installation Guide - Revision S

SV-EMS-221 D37

Pin

EMS 37-pin Harness Wire

Color

Sensor (with Dynon part number if

applicable)

1

Red

Voltmeter 1 (0 to 30 volts DC)

2

Yellow or Unwired

Voltmeter 2 (0 to 30 volts DC)

3

Black

Signal Ground

4

Violet/Blue

General Purpose Input 1

5

Black

Signal Ground

6

White/Yellow

General Purpose Input 11

7

White/Brown

General Purpose Input 12

8

Brown

Enhanced General Purpose Input 4

9

Brown/Blue

General Purpose Input 5

10

Brown/Yellow

General Purpose Input 6

11

Orange

General Purpose Input 7

12

Yellow

General Purpose Input 8

13

Black

Signal Ground

14

Yellow

Fuel Flow Input 1

15

Red

+12 volts DC Auxiliary Power Output

16

Black

Signal Ground

17

Black

Signal Ground

18

White/Red

+5 volts DC Auxiliary Power Output

(Limited to 300 mA by internal self-

resetting fuse)

19

White/Black

Fuel Flow Input 2

20

Orange/Brown

General Purpose Input 9

21

Orange/Blue

General Purpose Input 10

22

Violet/Yellow

Enhanced General Purpose Input 2

23

Violet/Green

Enhanced General Purpose Input 3

24

Orange/Green

Amps+ Input

25

Orange/Violet

Amps- Input

26

Green/Red

Manifold Pressure Input

27

Open

RPM Signal to Rotax 912 iS Prop Controller

(optional)

28

Open

NOTE: Must be grounded to common

ground with Prop Controller

29

Yellow/Green

Optional External Alarm Light

30

Black

Signal Ground

31

White/Orange

Enhanced General Purpose Input 13

32

White/Green

Standard RPM Left Input

33

White/Blue

Standard RPM Right Input

34

Blue

Low Voltage RPM Left Input

35

Green

Low Voltage RPM Right Input

36

Blue or Unwired

CAN High from 912 iS ECU

37

Green or Unwired

CAN Low CAN High from 912 iS ECU

Table 78 – SV-EMS-221 Male D37 Transducer Connector

Advertising