Dynon Avionics SkyView System Installation Guide User Manual
Page 182
SV-EMS-220/221 Installation and Configuration
7-70
SkyView System Installation Guide - Revision S
Example RPM Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
PIN #
FUNCTION
SENSOR
NAME
C37 P32/34
RPM
RPM
RPM
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the RPM Page (SETUP MENU > EMS SETUP > SENSOR SETUP > RPM RPM).
Configure RPM with the following properties:
ALARM:
OFF
MAXIMUM GRAPHICAL DISPLAY:
3000 RPM
MINIMUM GRAPHICAL DISPLAY:
0 RPM
SHOW SENSOR UNITS
YES
RANGE 1
o ENABLE
YES
o COLOR
GREEN
o TOP
2000 RPM
o BOTTOM
0 RPM
RANGE 2
o ENABLE
YES
o COLOR
YELLOW
o TOP
2250 RPM
o BOTTOM
2000 RPM
RANGE 3
o ENABLE
YES
o COLOR
GREEN
o TOP
2700 RPM
o BOTTOM
2250 RPM
RANGE 4
o ENABLE
YES
o COLOR
YELLOW
o TOP
2750 RPM
o BOTTOM
2700 RPM
RANGE 5
o ENABLE
YES
o COLOR
RED
o TOP
3000 RPM
o BOTTOM
2750 RPM
Figure 49 –
Anatomy of a
Widget: RPM