SV-D700 / SV-D1000 / SV-D1000T Installation and Configuration

4-8

SkyView System Installation Guide - Revision S

SV-BAT-320 can keep most SkyView systems operating for at least 60 minutes. The SV-BAT-320
does not supply (backup) power to the following SkyView system devices:

Autopilot servos

Heated AOA/Pitot Probe

SV-ADSB-470

SV-COM-425 / SV-COM-X83

SV-XPNDR-261/262

Any non-Dynon device

SkyView displays are only compatible with Dynon’s SV-BAT-320 backup battery. Do
not connect a lead-acid battery or any other battery to the connection reserved for
the SV-BAT-320 as the charging algorithm is optimized for the SV-BAT-320.
Connecting any other battery may have detrimental consequences. Damage
caused by connecting such a battery will not be repaired under warranty.

See the Homemade Wire Harness Considerations section for important
specifications that must be adhered to for the SV-BAT-320 to charge properly
when used with a non-Dynon harness.

SkyView Network Connectors

The two D9 connectors on the back of a SkyView display are SkyView network connectors. They
have identical pin-outs and are electrically connected inside the display (i.e., they are
completely interchangeable). Installers may use either connector or both connectors in SkyView
installations. Reference Table 76 on page 22-9 for SkyView Network Connector pin-out
information.

Note that these connectors are not serial port connectors.

Network Setup and Status

Once all SkyView modules are connected in a network, either in a bench top test or permanent
installation, turn the display(s) on. You will see the display boot up and the status LEDs on the
modules light up.

A tail number on the Aircraft Information Page (SETUP MENU > SYSTEM SETUP >
AIRCRAFT INFORMATION) is required for network configuration.

If you have more than one display in your SkyView system, the tail number only
needs to be set on the display that you initially perform the Network Configuration
on. At network configuration time, all other displays that are set to the default tail
number of DYNON will automatically have their settings and tail number
synchronized with the display the configuration is performed from. After
configuration, all displays’ tail numbers and settings will be synchronized, and