Dynon Avionics SkyView System Installation Guide User Manual

Page 139

Advertising
background image

SV-EMS-220/221 Installation and Configuration

SkyView System Installation Guide – Revision S

7-27

Example

Rotax

912 iS

(SV-

EMS-

221)Pin

EMS 37-pin Harness

Wire Color

Sensor (with Dynon part number if

applicable)

7

White/Brown

Not connected

8

Brown

Fuel pressure (101716-000)

9

Brown/Blue

Not connected

10

Brown/Yellow

Not connected

11

Orange

Not connected

12

Yellow

Flaps position potentiometer

13

Black

Available ground

14

Yellow

Fuel flow (100403-003)

15

Red

Fuel flow power (100403-003) / Oil pressure

(Honeywell and Rotax P/N 456180 only) sensor

power

16

Black

Available ground

17

Black

Available ground

18

White/Red

Manifold Pressure Sensor Power (+5 volt) / Kavlico

Pressure Sensors

19

White/Black

Return fuel flow (100403-003)

20

Orange/Brown

Fuel level left (resistive)

21

Orange/Blue

Fuel level right (resistive)

22

Violet/Yellow

Not connected

23

Violet/Green

Elevator position potentiometer

24

Orange/Green

Ammeter shunt + (100412-000)

25

Orange/Violet

Ammeter shunt -

26

Green/Red

Not connected

27

Open

RPM Signal to Rotax 912 iS Prop Controller

(optional)

28

Open

NOTE: Must be grounded to common ground with

Prop Controller

29

Yellow/Green

Optional External Alarm Light

30

Black

Not connected

31

White/Orange

Not connected

32

White/Green

Not connected

33

White/Blue

Not Connected

34

Blue

Not connected

35

Green

Not connected

36

Blue or Unwired

CAN High from 912 iS ECU

37

Green or Unwired

CAN Low from 912 iS ECU

Table 32 – Example Rotax 912 iS 37-pin Connector Sensor Map

The 912 iS ECU provides the following information to SkyView via a computerized CAN bus
interface:

Advertising