Autopilot Servo Installation, Configuration, and Calibration

SkyView System Installation Guide – Revision S

10-11

Servo Electrical Installation

Dynon Avionics’ servos are supplied with 7 unterminated wires, each about 8” in length. We
recommended that you use the SV-NET-SERVO (one per servo) network cabling kit when
installing servos; however, it is ultimately the responsibility of the installer to decide on
connectors and associated wiring.

Table 47 describes servo wire colors and functions.

Color

Function

SV-NET-SERVO

D9 Pin

Notes

Red

Power

N/A

10 to 30 volts DC*

Black

Aircraft Ground

N/A

Can be locally grounded

Green

SkyView Network

Data 1 A

1

Connected in parallel with

other SkyView Network

devices

Blue

SkyView Network

Data 1 B

6

Connected in parallel with

other SkyView Network

devices

Yellow

AP

Disengage/Control

Wheel Steering

(CWS) Button

N/A

Connected through a

normally-open pushbutton

switch to Ground (disengages
AP when button is pushed). If

two servos are installed, the

yellow wire from each servo is

connected in parallel to a

single pushbutton.

White/Green

SkyView Network

Data 2 A

8

Connected in parallel with

other SkyView Network

devices

White/Blue

SkyView Network

Data 2 B

4

Connected in parallel with

other SkyView Network

devices

Table 47 – Detailed Servo Wiring