Table 15 – Dynon Avionics SkyView System Installation Guide User Manual

Page 121

Advertising
background image

SV-EMS-220/221 Installation and Configuration

SkyView System Installation Guide – Revision S

7-9

Pin

EMS 37-pin

Harness Wire

Color

Function

Sensor Config

34

Blue

Low Voltage RPM Input Left

Do not connect to

magneto

35

Green

Low Voltage RPM Input Right

Do not connect to

magneto

36

Blue or Unwired

General Purpose TC Input 2+ (SV-EMS-220 only)

Thermocouple (SV-EMS-

220 only)

37

Green or Unwired

General Purpose TC Input 2- (SV-EMS-220 only)

Thermocouple (SV-EMS-

220 only)

Table 15 – SV-EMS-220/221 Male D37 Pin-to-Sensor Compatibility

Figure 29 – SV-EMS-220 37-pin Main Sensor Harness Female D37 Pin Insertion View (Rear)