Dynon Avionics SkyView System Installation Guide User Manual

Page 375

Advertising
background image

`

Appendix C: Wiring and Electrical Connections

SkyView System Installation Guide – Revision S

22-17

Explosion

9.0

Equipment identified as Category X

– no test required

Waterproofness

10.0

Equipment identified as Category X

– no test required

Fluids Susceptibility

11.0

Equipment identified as Category X

– no test required

Sand and Dust

12.0

Equipment identified as Category X

– no test required

Fungus

13.0

Equipment identified as Category X

– no test required

Salt Spray

14.0

Equipment identified as Category X

– no test required

Magnetic Effect

15.0

Equipment tested to Category Z

Power Input

16.0

Equipment tested to Category BX

Voltage Spike

17.0

Equipment tested to Category B

Audio frequency conducted
susceptibility

18.0

Equipment tested to Category B

Induced signal susceptibility

19.0

Equipment tested to Category AC

Radio frequency susceptibility

20.0

Equipment tested to Category TT

Radio frequency emission

21.0

Equipment tested to Category B

Lightning induced transient
susceptibility

22.0

Equipment identified as Category XXXX

– no test required

Lightning direct effects

23.0

Equipment identified as Category X

– no test required

Icing

24.0

Equipment identified as Category X

– no test required

Electrostatic Discharge

25.0

Equipment identified as Category X

– no test required

Fire, Flammability

26.0

Equipment identified as Category C

Nomenclature:

TT22 Mode S Transponder (Dynon Avionics SV-XPNDR-261)

Part Number: 00745-(XX)

ETSO: 2C112b, C166a

Manufacturer:

Trig Avionics Limited

Address:

Heriot Watt Research Park, Riccarton, Currie, Scotland, EH14 4AP

Conditions

DO-160F

Section

Description of Conducted Tests

Temperature and Altitude

4.0

Equipment tested to Categories A2, C1

Low temperature ground survival

4.5.1

-55°C

Low temperature short-time
operating

4.5.1

-40°C

Low temperature operating

4.5.2

-20°C

High temperature operating

4.5.4

+70°C

High temperature short-time
operating

4.5.3

+70°C

High temperature ground survival

4.5.3

+85°C

Loss of Cooling

4.5.5

Cooling air not required (+70°C operating without cooling air)

Altitude

4.6.1

35,000 feet

Decompression

4.6.2

8,000 to 35,000 feet in 15 seconds

Overpressure

4.6.3

-15,000 feet

Temperature Variation

5.0

Equipment tested to Category C

Humidity

6.0

Equipment tested to Category A

Operational Shocks

7.2

Equipment tested to Category B

Crash Safety

7.3

Equipment tested to Category B type 5