Dynon Avionics SkyView System Installation Guide User Manual

Page 137

Advertising
background image

SV-EMS-220/221 Installation and Configuration

SkyView System Installation Guide – Revision S

7-25

Example Rotax 912 (carbureted) (SV-EMS-220)

Pin

EMS 37-pin Harness

Wire Color

Sensor (with Dynon part number if

applicable)

1

Red

Battery voltage (voltmeter input)

2

Yellow or Unwired

Not connected

3

Black

Ground

4

Violet/Blue

Rotax CHT or oil (801-10-1)

5

Black

Ground

6

White/Yellow

Rotax oil pressure (Honeywell or Rotax P/N

456180)

7

White/Brown

Rotax CHT or oil (801-10-1)

8

Brown

Fuel pressure (100411-000 or 101690-000)

9

Brown/Blue

Heated pitot status (contact input)

10

Brown/Yellow

Not connected

11

Orange

Not connected

12

Yellow

Flaps position potentiometer

13

Black

Ground

14

Yellow

Fuel flow (100403-003)

15

Red

Fuel flow power (100403-003) / Oil pressure

(Honeywell and Rotax P/N 456180 only) sensor

power

16

Black

Ground

17

Black

Ground

18

White/Red

Manifold Pressure Sensor Power (+5 volt) / Kavlico

Pressure Sensors

19

White/Black

Not connected

20

Orange/Brown

Fuel level left (resistive)

21

Orange/Blue

Fuel level right (resistive)

22

Violet/Yellow

Rotax CHT or oil (801-10-1)

23

Violet/Green

Elevator position potentiometer

24

Orange/Green

Ammeter shunt + (100412-000)

25

Orange/Violet

Ammeter shunt -

26

Green/Red

Manifold Pressure (100434-000)

27

Open

Not connected

28

Open

Not connected

29

Yellow/Green

Optional External Alarm Light

30

Black

Not connected

31

White/Orange

Not connected

32

White/Green

RPM

33

White/Blue

Not Connected

34

Blue

Not connected

35

Green

Not connected

36

Blue or Unwired

Not connected

37

Green or Unwired

Not connected

Table 30 – Example Rotax 912 37-pin Connector Sensor Map

Advertising