SV-EMS-220/221 Installation and Configuration

7-40

SkyView System Installation Guide - Revision S

volts above ground, and crosses back down below 0.8V relative to ground to be counted as a
pulse.

For signals that have a peak voltage of 10-12V, either the Standard or Low Voltage RPM inputs
can be used.

Like the other methods above, you must know the number of pulses per revolution for your
RPM transducer.

Manifold Pressure Sensor

The Dynon Avionics Manifold Pressure Sensor (P/N 100434-000) is an integral assembly
consisting of three pins, a rubber seal, and a connector housing. Strip 3/16” insulation off the
ends of the three wires listed at right. Slide the three rubber seals onto the three wires and the
pins onto the ends of the wires. Crimp the 3 included pins onto the ends of the wires, ensuring
that the long tabs that cradle the rubber seal wrap around the seal (see picture at right for
example). For more details on preparing and crimping the Weather Pack pins, see

http://www.whiteproducts.net/faqs.shtml

.

Pin

Weather

Pack Pin

Color

Function

18

C

White/red

+5 volt

Auxiliary

26

B

Green/red

Manifold

pressure

17

A

Black

Ground

Note that you may need access to the SV-EMS-220/221’s +5 volt auxiliary supply for other
sensor installations, so make allowances for breaking out the connection to other areas. Route
the three wires to the location where you would like to mount the manifold pressure sensor.

Plug the crimped pins into the included Weatherpack connector. Now, mount the manifold
pressure sensor in a secure fashion using the mounting holes on either side of the sensor.

The pressure port on the manifold pressure sensor requires 1/4” inner diameter tubing for a
secure fit. You may need to use adapters to convert down to smaller inner diameter tubing for
your specific engine. We recommend that you use pipe clamps at every transition point,
including at the sensor itself.

Table 37 – Manifold Pressure Sensor Pins

Figure 34 – Detail view

of properly crimped pin.

C

B

A

Figure 35 – Pin

insertion (rear)

view of supplied

connector.

C

A

B

Figure 33 – Connection

diagram for sensor with

all black wires only

Advertising