background image

`

Appendix C: Wiring and Electrical Connections

SkyView System Installation Guide – Revision S

22-3

9-Pin Connector

Pin #

Wire Color

(Dynon Convention)

Signal Name

4

White/Blue

Data 2B

8

White/Green

Data 2A

In Dynon’s SkyView Network cables, power distribution pairs are also twisted together.

Pair #3:

9-Pin Connector

Pin #

Wire Color

(Dynon Convention)

Signal Name

2

Black

Ground 1

7

Red

Power 1

Pair #4:

9-Pin Connector

Pin #

Wire Color

(Dynon Convention)

Signal Name

3

White/Black

Ground 2

9

White/Red

Power 2

Individual wire, not twisted with any other wire:

9-Pin Connector

Pin #

Wire Color

(Dynon Convention)

Signal Name

5

Orange

EMS Aux

This signal is currently used only for SV-EMS-220/221 modules, but future modules may also
require this signal, so we recommend it be included if you are building your own SkyView
Network cables.

Heat Shrink Bundling and Strain Relief

All wires should be bundled together with heat shrink and then strain relieved when exiting the
connector shell or hood.

Advertising