Dynon Avionics SkyView System Installation Guide User Manual
Page 361
`
Appendix C: Wiring and Electrical Connections
SkyView System Installation Guide – Revision S
22-3
9-Pin Connector
Pin #
Wire Color
(Dynon Convention)
Signal Name
4
White/Blue
Data 2B
8
White/Green
Data 2A
In Dynon’s SkyView Network cables, power distribution pairs are also twisted together.
Pair #3:
9-Pin Connector
Pin #
Wire Color
(Dynon Convention)
Signal Name
2
Black
Ground 1
7
Red
Power 1
Pair #4:
9-Pin Connector
Pin #
Wire Color
(Dynon Convention)
Signal Name
3
White/Black
Ground 2
9
White/Red
Power 2
Individual wire, not twisted with any other wire:
9-Pin Connector
Pin #
Wire Color
(Dynon Convention)
Signal Name
5
Orange
EMS Aux
This signal is currently used only for SV-EMS-220/221 modules, but future modules may also
require this signal, so we recommend it be included if you are building your own SkyView
Network cables.
Heat Shrink Bundling and Strain Relief
All wires should be bundled together with heat shrink and then strain relieved when exiting the
connector shell or hood.