SV-EMS-220/221 Installation and Configuration

SkyView System Installation Guide – Revision S

7-69

Example Contact Sensor Setup

Assume this sensor was mapped on the Sensor Input Mapping Wizard as:

PIN #

FUNCTION

SENSOR

NAME

C37 P9

CANOPY

Contact

CANOPY

Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the CANOPY CONTACT Page (SETUP MENU > EMS SETUP > SENSOR SETUP > CANOPY
CONTACT).

Note that although inputs set up as contacts can physically accept up to 15V (so
that they can accept nominal aircraft voltage as one of their two states), the
maximum the EMS can measure is 5.0V. This means that as depicted below, the
two measured ranges should be set to 0-2.5V and 2.5-5V to measure the absence
and presence of power.

Configure CANOPY CONTACT with the following properties:

ALARM:

OFF

MAXIMUM GRAPHICAL DISPLAY:

5.0 VOLTS

MINIMUM GRAPHICAL DISPLAY:

0.0 VOLTS

RANGE 1

o ENABLE

YES

o NAME

OPEN

o COLOR

RED

o TOP

5.0 VOLTS

o BOTTOM

2.5 VOLTS

RANGE 2

o ENABLE

YES

o NAME

CLOSED

o COLOR

GREEN

o TOP

2.5 VOLTS

o BOTTOM

0.0 VOLTS

RANGE 3

o ENABLE

NO

o NAME

R3

o COLOR

GREEN

o TOP

20.0 VOLTS

o BOTTOM

10.0 VOLTS

RANGE 4

o ENABLE

NO

o NAME

R4

o COLOR

YELLOW

o TOP

10.0 VOLTS

o BOTTOM

5.0 VOLTS

RANGE 5

o ENABLE

NO