Ems sensor definitions, mapping, and settings -62, Ems sensor definitions -62, Ems sensor input mapping -62 – Dynon Avionics SkyView System Installation Guide User Manual

Page 174: Ems sensor input mapping, E ems sensor definitions, mapping, and settings, Ems sensor definitions, mapping, and settings

Advertising
background image

SV-EMS-220/221 Installation and Configuration

7-62

SkyView System Installation Guide - Revision S

When OIL TEMP is > 190° F, the OIL TEMP gauge will display different ranges:

100-120 and 230-266° F in YELLOW

120-230° F in GREEN

266-280° F in RED


The alarm type for oil temperature is the “self-clearing” type.

EMS Sensor Definitions, Mapping, and Settings

All sensors must be defined, mapped to SV-EMS-220/221 pins, and have their
settings configured.
This section describes how sensors are defined, mapped, and
set in SkyView.

EMS Sensor Definitions

All EMS sensor installations require a SkyView Sensor Definitions file. This file provides
characterizations of all sensors that SkyView supports, and is occasionally updated to add
additional supported sensors and correct issues with existing sensors. The most current version
of the SkyView Sensor Definitions file is preloaded onto each display prior to shipment. The
most current version of the SkyView Sensor Definitions file can be downloaded from

http://downloads.dynonavionics.com

. If you have more than one SkyView display, and the

SkyView Sensor Definitions file on each display is different from one another, a warning
message will be displayed:
EMS SFG FILE MISMATCH.

If you need to update the SkyView Sensor Definitions file, download the file and use the
instructions found in the How to Load and Delete Files Section.

The SkyView Sensor Definitions file has a .sfg file extension. This file is not
automatically shared between displays.
It must be loaded onto each display in the
system
.

EMS Sensor Input Mapping

In order to save installers time, Dynon provides preconfigured sensor mapping and
settings files which support popular four and six-cylinder engine installations. All of
the installations mentioned in the Example Engine Sensor and Transducer
Installations Section have preconfigured mapping and settings files that are
available for download at http://downloads.dynonavionics.com.

Settings for SV-EMS-220/221 pin mapping, ranges, widget graphical properties,
etc. are automatically shared between multiple SkyView displays.

If your engine installation is listed in the Example Engine Sensor and Transducer Installations
Section, we recommend you install one of the sensor mapping and settings files onto the