SV-AP-PANEL Installation

SkyView System Installation Guide – Revision S

18-7

Figure 116 – SV-AP-PANEL Trim control wiring diagram

Network Setup

As with all other SkyView Network devices, the SV-AP-PANEL must be configured into the
SkyView Network:

Go to SETUP MENU > SYSTEM SETUP > NETWORK SETUP > CONFIGURE > (right click) >
DETECT (button).

The SV-AP-PANEL(s) will be listed.

FINISH (button) > EXIT (button)

SkyView Configuration for SV-AP-PANEL (Trim Motor Control)

The SV-AP-PANEL’s trim controller can adjust the speed at which the trim motors run. In many
aircraft, this allows you have finer trim control for a given pushbutton press or hold by having
the trim motor movement slowed down at higher airspeeds.

SETUP MENU > HARDWARE CALIBRATION > TRIM CALIBRATION:

(If you connected trim control pushbuttons and the motors per Table 65 above, MOTOR 1 will
control PITCH trim.)