Dynon Avionics SkyView System Installation Guide User Manual
Page 331
SkyView System Installation Guide – Revision S
18-7
Figure 116 – SV-AP-PANEL Trim control wiring diagram
Network Setup
As with all other SkyView Network devices, the SV-AP-PANEL must be configured into the
SkyView Network:
Go to SETUP MENU > SYSTEM SETUP > NETWORK SETUP > CONFIGURE > (right click) >
DETECT (button).
The SV-AP-PANEL(s) will be listed.
FINISH (button) > EXIT (button)
SkyView Configuration for SV-AP-PANEL (Trim Motor Control)
The SV-AP-PANEL’s trim controller can adjust the speed at which the trim motors run. In many
aircraft, this allows you have finer trim control for a given pushbutton press or hold by having
the trim motor movement slowed down at higher airspeeds.
SETUP MENU > HARDWARE CALIBRATION > TRIM CALIBRATION:
(If you connected trim control pushbuttons and the motors per Table 65 above, MOTOR 1 will
control PITCH trim.)