background image

Autopilot Servo Installation, Configuration, and Calibration

10-12

SkyView System Installation Guide - Revision S

Power Consumption Section of the System Planning Chapter for details regarding servo current
consumption at 12 and 24 volts DC.

Circuit Breaker/Fuse

We recommend that electrical power for the autopilot servos be protected with an
appropriately sized circuit breaker or fuse that is accessible to the pilot while in flight.

SkyView continuously communicates with the servos even when the autopilot is disengaged. If
SkyView is operating, but the servos are not receiving power,

PTCH ERR

and

ROLL ERR

will be

displayed in Red on the top bar (AP STATUS area, to the left of the clock). Therefore, we
recommend that the servo power wiring be designed to receive power whenever SkyView is
powered on in routine operation. When the servos are receiving power but the autopilot is not
engaged, the servos draw negligible power.

SkyView Network Connection

Connect the servos to the SkyView network according to Figure 64 and Table 47. Installers
should strongly consider using the SV-NET-SERVO cabling kit (one per servo) for completing the
network connection to the servos in the system. Figure 65 is the recommended pin insertion
scheme for the three D9 connectors present in the SV-NET-SERVO cabling kit.

SV-NET-SERVO Kit

Female DB9 Connector

Pin Insertion View

SV-NET-SERVO Kit

Male DB9 Connector

Pin Insertion View

GREEN

BLUE

WHITE/BLUE

SERVO

(SV32, SV42,

or SV52)

1

5

6

9

SV-NET-SERVO Kit

Female DB9 Connector

Pin Insertion View

CONNECT

1

5

5

6

9

9

WHITE/BLUE

WHITE/GREEN

BLUE

GREEN

1

6

To SkyView

Network

SPLICE

SPLICE

SPLICE

RED

BLACK

YELLOW

RED - 20 AWG - To Servo Power Switch/Breaker

BLACK - 20 AWG - To Aircraft Ground

YELLOW - To Disengage/CWS Button

WHITE/GREEN

All wires in the kit are 20 feet long and 22 AWG unless otherwise specified.

Kit Contents

Figure 65 – SV-NET-SERVO Recommended Pin Insertion (All Connectors Rear View)

Unlike other SkyView Network devices, ONLY the SkyView Network data wires are
routed through the 9-pin connector. The servo Power (Red), Ground (Black), and
Disengage/CWS Button (Yellow) wires are not connected in the 9-pin connector. If
these wires were to connect to SkyView Network signals, the SkyView displays
(which supply power to the SkyView Network) can be damaged and require non-
warranty repair.

Advertising