SV-EMS-220/221 Installation and Configuration
7-68
SkyView System Installation Guide - Revision S
Example Voltmeter Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
PIN #
FUNCTION
SENSOR
NAME
C37 P1
VOLTS
VOLTAGE MEASURE
MAIN
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the MAIN VOLTS Page (SETUP MENU > EMS SETUP > SENSOR SETUP > MAIN VOLTS).
Configure MAIN VOLTS with the following properties:
ALARM:
OFF
MAXIMUM GRAPHICAL DISPLAY:
15.0 VOLTS
MINIMUM GRAPHICAL DISPLAY:
10.0 VOLTS
SHOW SENSOR UNITS
YES
RANGE 1
o ENABLE
YES
o COLOR
RED
o TOP
11.0 VOLTS
o BOTTOM
10.0 VOLTS
RANGE 2
o ENABLE
YES
o COLOR
YELLOW
o TOP
12.0 VOLTS
o BOTTOM
11.0 VOLTS
RANGE 3
o ENABLE
YES
o COLOR
GREEN
o TOP
13.6 VOLTS
o BOTTOM
12.0 VOLTS
RANGE 4
o ENABLE
YES
o COLOR
YELLOW
o TOP
14.6 VOLTS
o BOTTOM
13.6 VOLTS
RANGE 5
o ENABLE
YES
o COLOR
RED
o TOP
15.0 VOLTS
o BOTTOM
14.6 VOLTS
Figure 47 – Anatomy of a
Widget: Main Volts