Sv-adsb-470-related skyview display settings -8, Post installation checks -8 – Dynon Avionics SkyView System Installation Guide User Manual

Page 268

Advertising
background image

SV-ADSB-470 Installation, Configuration, and Testing

14-8

SkyView System Installation Guide - Revision S

A dual crimp style BNC connector can be completed using a wide range of commercial crimp
tools (for example the Tyco 5-1814800-3). The die apertures for the inner pin and the outer
shield should be approximately 1.72 mm and 5.41 mm respectively.

Strip back the coax cable to the dimensions in the table, as shown in the diagram below.
Slide 25 mm (1 inch) of heat shrink tubing over the cable.

Slide the outer crimp sleeve over the cable – it must go on before securing the center
contact.

Dimension

Cut size

(mm)

Cut size

(inches)

A

17.5

0.69

B

7.2

0.28

C

4.8

0.19

Crimp the center contact to the cable.

Insert the cable into the connector – the center contact should click into place in the
body, the inner shield should be inside the body of the connector and the outer shield
should be outside the body.

Crimp the outer sleeve over the shield.

Slide heat shrink tubing forward (flush to connector) and heat to shrink the tubing.

SV-ADSB-470-Related SkyView Display Settings

Before the ADS-B STATUS menu can be accessed, the SV-ADSB-470 needs to be configured on
the SkyView system:

SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL PORT x SETUP (the serial port you
wired the SV-ADSB-470 to) > SERIAL IN DEVICE > SV-ADSB-470 > ACCEPT (button).

SETUP MENU > TRAFFIC SETUP > SHOW TAIL NUMBERS > YES > ACCEPT (button).

Post Installation Checks

After the SV-ADSB-470 has been configured, confirmation that communication has been
established with the module by performing the following procedure:

Go to SETUP MENU > ADS-B STATUS.