Figure 40 installing the pedestal – Nortel Networks 1000M User Manual

Page 105

Advertising
background image

Floor mounting

105

Remove the pedestal from the carton and locate the four leveling
feet.

Install the feet into the base of the pedestal.

4

Install the cabinet on the pedestal.

Lean the cabinet backwards. From under the cabinet and with a
pair of pliers, break off the two tabs located in the openings on the
bottom of the cabinet where the door hinges join the cabinet, as
shown in

Figure 40 "Installing the pedestal" (page 105)

.

Figure 40
Installing the pedestal

Place the cabinet on the pedestal and make sure that it is properly
seated. Align with the guide at the rear of the cabinet and pedestal.
(Refer to

Figure 41 "Mounting the cabinet on the pedestal" (page

106)

.)

Install the four #14 screws that are shipped with the pedestal, two at
the bottom rear and two where the tabs were removed, and secure
the cabinet to the pedestal.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0