Installing and connecting reserve power supplies for the Cabinet system

The area must meet the following temperature limits:

Maximum allowed range: 0 to 45¡C (32 to 113¡F)
Recommended range: 20 to 35¡C (68 to 95 ¡F)

2

Remove the cover.

The cover is secured by one captive screw on the front of the box.
(Refer to

Figure 68 "Mounting the NTAK76 battery unit to the wall"

(page 152)

.)

3

Mount the battery unit to the wall using the four #8 20 mm (3/4 in.)
wood screws provided with the unit.

Install the center screw at the top of the battery unit. Level the unit
and install the remaining screws.

Figure 68
Mounting the NTAK76 battery unit to the wall

4

Set the switch on the front of the NTAK76 battery box to OFF. (Refer
to

Figure 69 "Jumper connections" (page 153)

).