Table 48 power failure transfer unit connections – Nortel Networks 1000M User Manual

Page 335

Advertising
background image

Connecting an attendant console

335

Physical slot

Logical slot

First TN...Last TN

Cable

Chassis

9

9

09 00...09 15

Card 9

Expander

10

10

10 00...10 15

Card 10

Expander

Note: Refer to the labels on the back of the chassis. See

Figure 106 "Cable connectors in a system

cabinet" (page 224)

.

Table 48
Power Failure Transfer Unit connections

QUA6 J1 Cable

Function

Pair

Color

Connects to

5T

5R

W-S
S-W

Connect to the telephone

6T

6R

R-BL
BL-R

Connect to the telephone line card

7T

7R

R-O
O-R

Connect to the Central Office trunk

PFT 1

8T

8R

R-G
G-R

Connect to the trunk line card

9T

9R

R-BR
BR-R

Connect to the telephone

10T

10R

R-S
S-R

Connect to the telephone line card

11T

11R

BK-BL
BL-BK

Connect to the Central Office trunk

PFT 2

12T

12R

BK-O
O-BK

Connect to the trunk line card

13T

13R

BK-G
G-BK

Connect to the telephone

14T

14R

BK-BR
BR-BK

Connect to the telephone line card

15T

15R

BK-S
S-BK

Connect to the Central Office trunk

PFT 3

16T

16R

Y-BL
BL-Y

Connect to the trunk line card

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.