Connecting the telephones

Refer to

"Preprogrammed data" (page 373)

for default DN

assignments.

Now, you can activate the telephone, as described in

"Activating

telephones" (page 336)

.

—End—

Connecting analog 500/2500-type telephones with a PFTU

Procedure 63

Connecting 500/2500-type telephones with a PFTU

Step

Action

1

Locate the telephone terminations on the cross-connect terminal.

2

Connect one end of the cross-connect wire to the leads of the
telephone.

3

Locate the PFTU connections (unit PFT 1 through PFT 5) assigned
to this telephone at the cross-connect terminal.

Refer to

Table 48 "Power Failure Transfer Unit connections" (page

335)

.

4

Connect the other end of the cross-connect wire to the pair assigned
to the telephone on the PFTU.

5

Connect a second cross-connect wire to the pair assigned to the line
card on the PFTU.

6

Locate the line card terminations on the cross-connect terminal.

For the Cabinet system, refer to:

Table 45 "Terminal number assignments: Main and Expansion
Cabinets 1 and 2" (page 332)

for the main cabinet and Expansion

Cabinets 1 and 2

Table 46 "Terminal number assignments: Expansion Cabinets 3
and 4" (page 333)

for Expansion Cabinets 3 and 4

For the Chassis system, refer to:

Table 47 "Terminal Number assignments: Chassis and chassis
expander" (page 334)

for the chassis and chassis expander

7

Connect the other end of the cross-connect wire to the assigned
TN terminal block.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.