92

Installing the Chassis system

4. Make sure that you have created the equipment layout plan and card

slot assignment plan. See Communication Server 1000M and Meridian
1 Small System Planning and Engineering (NN43011-220)
.

5. If your Small System requires earthquake bracing, refer to

"Bracing

against earthquakes" (page 63)

.

For your system to be braced against earthquakes, you must install the
chassis on a wall in a vertical position.

6. Locate the box containing the Small System equipment.

7. Install the chassis. See

"Mounting the chassis" (page 107)

. Refer to one

of the following procedures, depending on the position in which you will
install the chassis:

Procedure 8 "Installing the chassis in a 480 mm (19 in.)
rack/equipment cabinet" (page 110)

Procedure 9 "Installing the chassis on a wall in a vertical position"
(page 114)

Procedure 10 "Installing the chassis on a wall in a horizontal
position" (page 119)

8. Install the chassis expander. See

"Connecting the chassis expander

to the chassis" (page 123)

. You can skip this step if your system only

has one chassis.

Install the chassis expander the same way as the chassis. Refer to

Procedure 11 "Adding a chassis expander" (page 123)

. This procedure

describes how to connect the chassis to the chassis expander by using
the two NTDK95 CE-MUX/DS-30X cables.

Note: To ensure correct usage, one end of the NTDK95 cable is
designated to connect to the expansion cabinet.

Figure 31
Expansion Cabinet end of NTDK95 cable

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008