Procedure 23 – Nortel Networks 1000M User Manual

Page 170

Advertising
background image

170

Installing fiber expansion

CAUTION

Service Interruption

Incorrectly connected fiber-optic cables may cause the following
problems:

a series of repetitive fault-indicating messages

a complete failure of the expansion cabinet

If fault-indicating messages appear, check the fiber-optic cable
connections.

Since messages are stored in a buffer, they may continue to
be displayed until the buffer is empty. After checking the cable
connections, wait a couple of minutes for the messages to stop.

Procedure 23

Installing the A0632902 10m plastic fiber-optic cable

Step

Action

1

Put on the antistatic wrist strap.

2

Place the SSC card on a clean, flat, ESD-dissipated surface.

3

Remove the protective plugs from the connectors on the Fiber
Expansion daughterboard.

4

Connect the fiber-optic cable to the Fiber Expansion daughterboard,
making sure that the "V"-shaped groove on the cable connector is
facing outward and that the connector is fully seated. See

Figure 78

"Plastic fiber cable connection on dual-port daughterboard" (page
171)

.

The mark (if equipped) on the sides of the cable connector should
not be visible when properly connected. Refer to

Figure 78 "Plastic

fiber cable connection on dual-port daughterboard" (page 171)

.

5

Route the fiber cable through the SSC cable router on the SSC card.

6

Insert the SSC card into slot 0 of the Main Cabinet or Chassis. Lock
card into faceplate latches.

7

Route the cables through the SSC Cable Routing Guide as shown in

Figure 79 "Fiber-optic cable connection" (page 172)

.

Note: Be sure to wrap the cable a minimum of one complete
loop around the Cable Routing Guide to allow for extra cable for
removing the SSC card later.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.