Terminal block requirements – Nortel Networks 1000M User Manual

Page 214

Advertising
background image

214

Installing and connecting cross-connect terminals

Terminal block requirements

This section describes the respective terminal block requirements for the
Cabinet system and the Chassis system.

Terminal block requirements for the Cabinet system

The cross-connect terminal requires sufficient connecting blocks to
terminate the following:

•

up to ten 25-pair cables from each cabinet

— Each slot that is equipped with a trunk or line circuit card requires

a cable.

–

The connectors J1 through J10 correspond to slot numbers 1
through 10 in the main cabinet.

–

Connectors J1 through J10 correspond to slot numbers 11
through 20 in the first expansion cabinet.

–

Connectors J1 through J10 correspond to slot numbers 21
through 30 in the second expansion cabinet.

–

Connectors J1 through J10 correspond to slot numbers 31
through 40 in the third expansion cabinet.

–

Connectors J1 through J10 correspond to slot numbers 41
through 50 in the fourth expansion cabinet.

–

Allow for additional cables at the cross-connect terminal if any of
the ten slots in each cabinet are initially left vacant.

— If the NTAK19 SDI cable is not used with the NTAK02 card, then a

25-pair cable is required.

•

nine conductors comprising the AUX cable from each cabinet

•

one 25-pair cable from each QUA6 PFTU

•

wiring from telephones and trunks

Terminal block requirements for the Chassis system

The cross-connect terminal requires enough connecting blocks to terminate
the following wires:

•

for the NTAK09 circuit card, use the NTBK04 cable

•

for the NTAK10, NTAK79, and NTBK50 circuit cards, use the NTBK05
cable

•

up to five 25-pair cables from each chassis

— Each slot that is equipped with a trunk or line circuit card requires

a cable.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.