Table 52 power failure transfer unit connections, For pftu – Nortel Networks 1000M User Manual

Page 348

Advertising
background image

348

Connecting the trunks

Table 52
Power Failure Transfer Unit connections

QUA6 J1 cable

Function

Pair

Color

Connects to

Comments

5T

5R

W-S
S-W

Connect to the telephone

6T

6R

R-BL
BL-R

Connect to the telephone line
card

Connect to TN assigned to the
telephone

7T

7R

R-O
O-R

Connect to the Central Office
trunk

P
F
T

1

8T

8R

R-G
G-R

Connect to the trunk line card

Connect to TN assigned to the
trunk

9T

9R

R-BR
BR-R

Connect to the telephone

10T

10R

R-S
S-R

Connect to the telephone line
card

Connect to TN assigned to the
telephone

11T

11R

BK-BL
BL-BK

Connect to the Central Office
trunk

P
F
T

2

12T

12R

BK-O
O-BK

Connect to the trunk line card

Connect to TN assigned to the
trunk

13T

13R

BK-G
G-BK

Connect to the telephone

14T

14R

BK-BR
BR-BK

Connect to the telephone line
card

Connect to TN assigned to the
telephone

15T

15R

BK-S
S-BK

Connect to the Central Office
trunk

P
F
T

3

16T

16R

Y-BL
BL-Y

Connect to the trunk line card

Connect to TN assigned to the
trunk

17T

17R

Y-O
O-Y

Connect to the telephone

18T

18R

Y-G
G-Y

Connect to the telephone line
card

Connect to TN assigned to the
telephone

19T

19R

Y-BR
BR-Y

Connect to the Central Office
trunk

P
F
T

4

20T

20R

Y-S
S-Y

Connect to the trunk line card

Connect to TN assigned to the
trunk

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.