Connecting trunks with pftu, Procedure 72 connecting trunks with pftu – Nortel Networks 1000M User Manual

Page 347

Advertising
background image

Connecting trunks with PFTU

347

Table 53 "NT8D14 Universal Trunk: modes and option settings"
(page 349)

to

Table 55 "NT8D15 E and M Trunk card" (page 351)

list

the connections for trunks. For trunk connections for Europe, see

Table 56 "E and M TIE trunk card (2-wire)" (page 353)

to

Table 64

"Central Office trunk connections" (page 360)

. For trunk connections

for the UK, see

Table 65 "NT5K17 DID cross-connect terminations"

(page 361)

to

Table 71 "NT5K19 Recorded Announcement mode

pair terminations" (page 365)

.

—End—

Connecting trunks with PFTU

Procedure 71

Connecting trunks with PFTU

Step

Action

1

Locate the PFTU terminal blocks at the cross-connect terminal.

2

Cross-connect the first pair of the assigned PFT to the telephone.

Refer to

Table 52 "Power Failure Transfer Unit connections" (page

348)

for PFTU connections.

3

Cross-connect the second pair of the PFT to the TN assigned to
the telephone.

4

Cross-connect the third pair of the PFT to the Central Office trunk.

5

Cross-connect the third pair of the PFT to the TN assigned to the
trunk.

6

Repeat for each trunk assigned to the PFTU.

—End—

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.