Figure 110 j1 cable labels, Table 31 control and power connections on cable j1, Procedure 43 installing the pftu – Nortel Networks 1000M User Manual

Page 230

Advertising
background image

230

Installing Power Failure Transfer Units

Procedure 42

Installing the PFTU

Step

Action

1

Mount the PFTU on the wall near the system cross-connect terminal
and secure it with four screws.

2

Install an NE-A25B-type 25-pair cable from connector J1 on the
faceplate of the PFTU to its assigned location at the cross-connect
terminal.

3

Label the pairs of the J1 cable on the cross-connect terminal block
as shown in

Figure 110 "J1 cable labels" (page 230)

.

Figure 110
J1 cable labels

4

Connect the PFTU power and control connections to the AUX
cable from the cabinet or chassis. See

Table 31 "Control and

power connections on cable J1" (page 230)

. For the location of the

Auxiliary port on the cabinet, see

Figure 111 "Auxiliary port location

on cabinet" (page 232)

. For the location of the AUX connector on

the chassis, see

Figure 111 "Auxiliary port location on cabinet"

(page 232)

.

Table 31
Control and power connections on cable J1

J1 Cable from QUA6 (see

Figure 113 "Power fail transfer" (page 234)

)

Function

Pair

Number

Pair

Color

Connects to

Cross-connect to

Control

1T

W-BL

(ALM)

Not used.

1R

BL-W

BRTN

W-BL 1-dot connection on
AUX cable from the cabinet
or chassis.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.