Main components of the Chassis system

53

modems or Data Communication Equipment (DCE) for remote access
to the system

on-site Data Terminating Equipment (DTE) or TTY terminal for accessing
the system

connecting blocks for the cross-connect terminal

transformers and centralized power supplies for items such as digit
displays on telephones

optional equipment such as music sources, RAN machines, paging
equipment, and CDR devices

NT1R20 Off-Premise Station Analog Line Card. Each card has eight
ports. Each of the units on the card can be configured to be operated as
an OPS or in an On-Premise (ONS) configuration

additional Modem Eliminator (NULL Modem without hardware
handshaking). The A0601397 converter may be required to interface
the DTE to the system.

industry-standard Ethernet Media Access Unit (MAU)

NTTK43 EMC grounding clip is required, for EMC compliance, on the
fan baffle on the lower right-hand side of chassis using 100BaseT
connections. Refer to

Figure 20 "EMC grounding clip on the chassis"

(page 53)

.

Figure 20
EMC grounding clip on the chassis

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.