Connecting the trunks

NT5K18 Exchange line trunk card terminations

Cross-connect the NT5K18 Exchange line trunk card as shown in

Table 66

"NT5K18 Exchange line trunk card cross-connect terminations" (page 362)

.

Note: The connections on the NT5K18 Exchange line trunk card are
polarity sensitive. Make sure the ground side of the trunk is connected
to the A leg of the NT5K18 circuit. Make sure the -50 V side of the trunk
is connected to the B leg of the NT5K18 circuit.

Table 66
NT5K18 Exchange line trunk card cross-connect terminations

Pair

Pins

Pair color

Unit #

T0

R0

26

1

W-BL
BL-W

27

2

W-O
O-W

0

T1

R1

28

3

W-G
G-W

29

4

W-BR
BR-W

1

T2

R2

30

5

W-S
S-W

31

6

R-BL
BL-R

2

T3

R3

32

7

R-O
O-R

33

8

R-G
G-R

3

T4

R4

34

9

R-BR
BR-R

35
10

R-S
S-R

4

T5

R5

36
11

BK-BL
BL-BK

37
12

BK-O
O-BK

5

T6

R6

38
13

BK-G
G-BK

39
14

BK-BR
BR-BK

6

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.