Installing the Chassis system

For a system with IP expansion, refer to

"Installing IP expansion"

(page 179)

.

b. Install the NTDK16 48-port Digital Line Card in slot 4 of the chassis.

See

Procedure 36 "Installing the NTDK16 48-port Digital Line Card"

(page 210)

.

The NTDK16 Digital Line Card is not required for the Small System
to operate.

13. Install the optional circuit cards that you wish to have in your Small

System. Refer to

"Installing optional circuit cards" (page 193)

and ISDN

Basic Rate Interface Maintenance (NN43001-718). Also, refer to your
card slot assignment plan.

14. Install the cross-connect terminal. See

"Installing and connecting

cross-connect terminals" (page 213)

.

Refer to the following procedures:

Procedure 38 "Installing the BIX cross-connect terminal" (page 215)

Procedure 39 "Installing the Krone Test Jack Frame (UK)" (page
219)

15. Install the cables from the chassis to the cross-connect terminal. See

"Installing and connecting cross-connect terminals" (page 213)

. Refer

to

Procedure 41 "Connecting the cables for the Chassis system" (page

225)

.

16. Install the PFTUs, if provided. See

"Installing Power Failure Transfer

Units" (page 229)

. Refer to

Procedure 42 "Installing the PFTU" (page

230)

.

17. Connect the SDI port cable at the back of the chassis. See

"Installing

and connecting SDI and Ethernet network interfaces" (page 237)

. Refer

to

Procedure 43 "Connecting SDI ports on the SSC card" (page 242)

.

18. If Ethernet is required, insert an industry-standard Media Access Unit

(MAU) directly into the Ethernet connector at the back of the chassis.
The Chassis system does not include the MAU. Insert the Ethernet
cable into this MAU. See

"Installing and connecting SDI and Ethernet

network interfaces" (page 237)

. Refer to

Procedure 47 "Connecting the

Ethernet cable to the Chassis system" (page 256)

.

19. Make sure that the DIP switch settings on the power supply are set to

the correct values for ringing voltage, ringing frequency, and message
waiting voltage. See

Table 6 "Power supply DIP switch settings" (page

44)

through

Table 9 "North American power supply DIP switch settings"

(page 45)

for the DIP switch settings.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.