Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 134

Advertising
background image

6-5

IM 04L31A01-17E

Command

6

Command Command Function

Execution mode

ADMINISTRATOR

USER Page

Type

Name

Event Setting

ET

Sets the time event

Operation mode

Yes

No

6-21

EP

Sets the PV event

Operation mode

Yes

No

6-22

Event Output Setting

EO

Sets the event output

Operation mode

Yes

No

6-22

PA

Program pattern end signal

Operation mode

Yes

No

6-22

Repeat Action Setting

PR

Sets the repeating action

Operation mode

Yes

No

6-22

Program End

PE

End programming

Operation mode

Yes

No

6-22

Auto message for program Run/Reset

PK

Set the auto message for program run/reset Operation mode

Yes

No

6-22

Program display position

PL

Set the program display position

Operation mode

Yes

No

6-22

Auto change to program run display

MQ

Auto change to program run display

Operation mode

Yes

No

6-22

Event display group

PV

Set the event display group

Operation mode

Yes

No

6-22

Detail Settings (Control Function Settings)

HF

Sets the setpoint

Operation mode

Yes

No

6-23

GL

Sets the output velocity limiter

Operation mode

Yes

No

6-23

GA

Sets the anti-reset windup function

Operation mode

Yes

No

6-23

Detail Settings (Hysteresis (Alarm, PV Event))

AP

Sets the alarm hysteresis

Operation mode

Yes

No

6-23

PH

Sets the PV event hysteresis

Operation mode

Yes

No

6-23

Detailed settings (DIO operation monitoring and function settings)

DX

Set the DIO operation monitoring function

Operation mode

Yes

No

6-23

DY

Set the DIO operation monitoring function

Operation mode

Yes

No

6-24

tag and tag comment

DZ

Set the DIO operation monitoring function

Operation mode

Yes

No

6-24

label and display color

Detailed settings (DI/DO label settings)

DW

Set the DI/DO label

Operation mode

Yes

No

6-24

Control computation

MT

Se the equation

Operation mode

Yes

No

6-25

MU

Se the computation error

Operation mode

Yes

No

6-25

MV

Se the logic computation

Operation mode

Yes

No

6-25

MX

Se the computation constant

Operation mode

Yes

No

6-25

DU

Se the remote bias

Operation mode

Yes

No

6-25

External Loop Setting (PID Parameter)

DT

Sets the external loop PID parameter

Basic setting mode

Yes

No

6-26

External Loop Setting (Control Parameter)

DV

Sets the external loop control parameter

Basic setting mode

Yes

No

6-26

Yes: Command usable

No: Command not usable

6.2 A List of Commands