Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 228

Advertising
background image

7-36

IM 04L31A01-17E

CX1000
bit0: Loop 1 (1:assigned, 0: unassigned)
bit1: Loop 2 (1:assigned, 0: unassigned)
bit2–bit7:

0

Measurement/Computation/Control Channel Alarm Types, Output of Settings (Style
Number S3 or Later)

• Measurement/computation/control channel alarm types, and settings are output using

the FS command.

• The output format identifier is 1. See page 7-3, “Identifier.”

2 bytes

Number of blocks

Block 1

. . .

Block n

Number of bytes

2 bytes

BINARY data
(The BINARY data section
on the “Conceptual diagram”
on page 7-2.)

Number of Blocks

This is the number of blocks.

Number of Bytes

This is the size of one block in bytes.

Blocks

Year

Month

Day

SP

• • •

SP

• • •

SP

• • •

SP

• • •

Hour

Alarm level

• • •

Alarm level

• • •

Alarm level

• • •

Alarm level

• • •

Minute

Alarm type

• • •

Alarm type

• • •

Alarm type

• • •

Alarm type

• • •

Millisecond

Alarm settings

• • •

Alarm settings

• • •

Second

(Reserved)*

• • •

(Reserved)*

• • •

(Reserved)*

• • •

(Reserved)*

• • •

Alarm settings

• • •

1 byte

1 byte

1 byte

1 byte

1 byte

1 byte

2 bytes

4 bytes

Measurement channel

• • •

Math channel

• • •

Control channel

• • •

Channel(Green Series)

• • •

* The sections indicated as (Reserved) are not used. The value is fixed to “0.”

Data details

Channel number
CX2000:1-20, 31-60, 101-118, 201-248
CX1000:1-3, 31-48, 101-106, 201-212
SP
Target setpoint number (0 for other than control channels)1-8
The top bit of the currently used target setpoint number data is 1.
Alarm level
0-3
Alarm type
0-31
For the correspondence between the alarm type and number, see the alarm status of
“Measured/Computed/Control Data, and FIFO Data” on page 7-27.
Alarm settings
0 when the alarm type is 0 (no alarm). Not output on external temperature meter
channels.

7.3 Output Format of BINARY Data