6-38

IM 04L31A01-17E

6.6 Setting Commands (Operation)

Description • EV3 is valid when display data are being

acquired to the internal memory, and the CX

is set to store the data to the external storage

medium using auto save. The display data

residing in the internal memory can be stored

to the external storage medium at arbitrary

times.

• EV4 is valid when event data are being

acquired to the internal memory in the free run

mode, and the CX is set to store the data to

the external storage medium using auto save.

The event data residing in the internal

memory can be stored to the external storage

medium at arbitrary times.

MS

Writes the message (display and
save)

Syntax

MS p1<terminator>
p1: Message number (1 to 8)

Example

Write the message of message number 8.

MS8

Description This command displays the message to the

screen and writes the message in the display

data and event data.

TL

Starts/stops/resets computation
(MATH)/clears the computation
dropout status display

Syntax

TL p1<terminator>
p1: Operation type

0

Start computation

1

Stop computation

2

Reset computation

3

Clear the computation dropout status

display

Example

Starting the computation.

TL0

Description • This command cannot be executed while

setup data are being saved or loaded.

• This command can be used on models with

the computation function option /M1.

DS

Switches execution modes
(operation/basic setting)

Syntax

DS p1<terminator>
p1: Mode type

0 Operation mode

1 Basic setting mode

Example

Set the mode to basic setting mode.

DS1

Description • Parameter p1 cannot be set to 1 while

measurement/computation is in progress,

while the external storage medium is being

formatted, or while data are being saved to

the external storage medium.

• Parameter p1 cannot be set to 0 while the

external storage medium is being formatted or

while data are being saved to the external

storage medium.

• To activate the settings that are changed

using the basic setting commands, the

settings must be saved using the XE

command. Make sure to save the settings

with the XE command before changing from

the basic setting mode to the operation mode.

Otherwise, new settings will not be activated.

LO

Loads the setup data for setting
commands

Syntax

LO p1<terminator>
p1: File name (up to 8 characters)

Example

Load the setting data of setting commands from

the setup file SETFILE1 (.pcl extension).

LOSETFILE1

Description • This command cannot be used to load the

setup data of the basic setting commands. To

load the setup data of both setting and basic

setting commands, use the YO command.

• This command cannot be specified on models

that do not have an external storage device or

when a medium is not inserted into the drive.

• This command cannot be used while the

setup data file is being output (specified using

the FE command).

• This command cannot be used while program

control is in execution.