Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 297

Advertising
background image

App-38

IM 04L31A01-17E

Parameters Related to Loop 6

D3501-D3519

D3601-D3612

D3625-D3628

D3631-D3642

D3655-D3658

D3661-D3672

D3685-D3688

D3691-D3702

D3715-D3718

D3721-D3732

D3745-D3748

D3751-D3762

D3775-D3778

D3781-D3792

D3805-D3808

D3811-D3822

D3835-D3838

Parameter per
Loop
PID parameter of
PID number 1 of
loop 6
Control alarm
value of PID
number 1 of loop 6
PID parameter of
PID number 2 of
loop 6
Control alarm
value of PID
number 2 of loop 6
PID parameter of
PID number 3 of
loop 6
Control alarm
value of PID
number 3 of loop 6
PID parameter of
PID number 4 of
loop 6
Control alarm
value of PID
number 4 of loop 6
PID parameter of
PID number 5 of
loop 6
Control alarm
value of PID
number 5 of loop 6
PID parameter of
PID number 6 of
loop 6
Control alarm
value of PID
number 6 of loop 6
PID parameter of
PID number 7 of
loop 6
Control alarm
value of PID
number 7 of loop 6
PID parameter of
PID number 8 of
loop 6
Control alarm
value of PID
number 8 of loop 6

Same as the parameters for loop
1*

2

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the PID parameters of
PID number 1 of loop 1

Same as the control alarm values
of PID number 1 of loop 1

Same as the range for the parameters for
loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

Same as the range for the PID parameters
of PID number 1 of loop 1

Same as the range for the control alarm
values of PID number 1 of loop 1

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

D Register

Number

Description

Register Type

Value

Read/

Write

*2 Loops 5 and 6 do not have Remote, bias setting against PV range, filter setting, ratio setting, and

remote/local switching.

Appendix 6 Register Assignments