Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 124

Advertising
background image

2-7

IM 04L31A01-01E

Installation and Wiring

3

2

1

4

5

6

7

8

9

10

11

12

13

14

Terminal Arrangements of the Control DIO Expansion Terminal Block (Option
Terminal Block Provided with the /CST1 Option)
12 contact input and 12 transistor contact output terminals are arranged as shown in the
following figure. Wire the terminals according to the configuration.

DIGITAL OUT

11
12

C

10

11
12

C
C
C

9

10

C

7
8
C

5
6

3
4

1
2

5

6

3

4

8

9

7

1
2

C

DIGITAL IN

Transistor output

Contact input

C: Common

DIGITAL OUT terminals 1 to 12 are indicated using the following numbers when the
control DIO expansion terminal block EXTDIO is selected in the contact (relay) output
registration setting.
RO001 to RO012
In addition, DIGITAL IN terminals 1 to 12 are indicated using the following numbers when
the control DIO expansion terminal block EXTDIO is selected in the contact input
registration setting.
RI001 to RI012

Terminal Arrangements of the Measurement Alarm Option Terminal Block
The measurement alarm option terminal block is the terminal block that you specified as
an option at the time of purchase. The following four types are available.
/A6:

6 measurement alarm outputs

/A6R:

6 measurement alarm outputs and 8 measurement remote inputs

/A4F:

4 measurement alarm outputs, 1 FAIL output, and 1 memory end output

/A4FR: 4 measurement alarm outputs, 1 FAIL output, 1 memory end output, and 8

measurement remote inputs.

The following figure shows the terminal arrangements on each measurement alarm
option terminal block. Wire the terminals according to the configuration.

ALARM

06

NC

NO

C

05

NC

NO

C

04

NC

NO

C

03

NC

NO

C

02

NC

NO

C

01

NC

NO

C

ALARM

REMOTE

06

NC

NO

C

05

NC

NO

C

04

NC

NO

C

03

NC

NO

C

02

NC

NO

C

01

6

7

8

3

4

5

C

1

2

NC

NO

C

Alarm output

• /A6 option

Measurement remote input

• /A6R option

C: Common
NO: Normally Opened
NC: Normally Closed

Alarm output

• /A4F option

Measurement remote input

• /A4FR option

C: Common
NO: Normally Opened
NC: Normally Closed

ALARM

REMOTE

01

02

03

04

FAIL

ALARM

MEMORY

MEMORY

02

01

03

04

FAIL

C

1

2

3

4

5

6

7

8

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

C

Memory end output

FAIL output

ALARM terminals 01 to 06 are indicated using [I01] to [I06] in the measurement alarm
output settings (see section 7.2, “Setting Related to Measurement alarm ”).
REMOTE terminals 1 to 8 are indicated using numbers 1 to 8 in the measurement
remote output settings (see section 11.5, “Setting the Measurement Remote Input”).

2.3 Wiring