Func key operation in operation mode, Key operations on the control operation display – Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 147

Advertising
background image

3-6

IM 04L31A01-01E

FUNC Key Operation in Operation Mode

The following operation can be carried out in operation mode.

Menu

Reference

Function (conditions displayed on the soft key menu)

Alarm ACK

4.7, 7.2

Clears alarm display/relay output (valid only when the operation of
the alarm display or output relay is set to “hold”).

Message

8.9

Displays messages 1 to 8 on the trend display and writes them to
the internal memory.

Manual sample 9.2

Acquires instantaneous values of all channels to the internal memory.

Key lock

11.2

Enables/disables key lock (only when key lock is used)

Log out

11.3

Logs out (only when logged in using the key login function)

Trigger

9.1

Trigger used to start acquiring event data to the internal memory (valid
only when event data is specified to be acquired to the internal memory
and the trigger used to start the acquisition is set to key trigger).

Math START/

10.2

Starts/stops computation (only for models with the computation option

Math STOP

(/M1))

Math reset

10.2

Resets the computed value of the computation channel to 0 (only on
models with the computation option (/M1) while the computation is
stopped).

Math ACK

10.2

Recovers the computation dropout indication icon to normal
indication (only on models with the computation function (/M1) when
computation dropout occurs)

Snapshot

9.6

Saves the screen image data to the external storage medium.

Log

11.4

Displays the log display/system display.

FTP test

Communications

*

Executes an FTP test.

4Panel

8.2

Sets the name of the 4 screen display (only when the 4 screen
display is showing)

Save Display/ 9.1

Stores the display data or event data to the external storage medium

Save Event

(only when the display data or event data is being acquired to the
internal memory in the free mode).

E-Mail START/ Communications

*

Enables/disables the e-mail transmission function.

E-Mail STOP
E-Mail test

Communications

*

Sends test messages to recipient 1 and 2.

Modbus master Communications

*

Displays the Modbus status when the Modbus master function is used.

External loop Communications

*

Displays the status of the external Green series communication

communications.

* See the

DAQSTATION CX1000/CX2000 Communication Interface User’s Manual (IM04L31A01-17E)

.

Procedure

START

STOP

ESC

MENU

DISP/

ENTER

USER

FUNC

Soft keys

FUNC key

1

ABC

2

DEF

3

GHI

4

JKL

5

MNO

6

PQR

7

STU

8

VWX

0

9

YZ

ESC key

1. Press the

FUNC key

.

As shown in the following figure, menu assigned to the soft keys is displayed.

2. Press the

soft key

corresponding to the function you wish to execute.

If [Next 1/n] (where n is the number of menu lines) appears at the right end of the
menu, this indicates that there are multiple lines of menus. Press the [Next 1/n] soft
key to view the next menu.
Press a soft key to execute the function assigned to it. The result of the soft key being
pressed varies depending on its function, as is explained in later sections of this manual.
To clear the menu without executing functions, press the FUNC or ESC key.

Key Operations on the Control Operation Display

On the control operation displays such as the control group display and tuning display, a
soft key menu appears at the bottom of the display. For the operating procedure, see
chapter 6, “Operations during Control Operation.”

3.2 Basic Key Operations