Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 358

Advertising
background image

14-10

IM 04L31A01-01E

Display data file only

Event data file only

Number of control loops: 10 loops, measurement channels: 10 channels
computation channel: 0 channels

Display update
rate (min/div)

Save interval (s)
Sample length

1 min

2 s

Approx. 4 h

5 min

10 s

Approx. 20 h

20 min

40 s

Approx. 3 days

30 min

60 s

Approx. 5 days

60 min

120 s

Approx. 10 days

240 min

480 s

Approx. 40 days

Save interval
Sample length

1 s

Approx. 4 h

5 s

Approx. 20 h

30 s

Approx. 5 days

120 s

Approx. 20 days

Event data file only

Display update
rate (min/div)

Save interval (s)
Sample length

1 min

2 s

Approx. 3 h

5 min

10 s

Approx. 15 h

20 min

40 s

Approx. 2 days

30 min

60 s

Approx. 3 days

60 min

120 s

Approx. 7 days

240 min

480 s

Approx. 30 days

Display data file

Display data file + event data file

Save interval
Sample length

1 s

Approx. 1 h

5 s

Approx. 5 h

30 s

Approx. 29 h

120 s

Approx. 5 days

Manual sampled data:

Trigger: Key operation, communication command, or remote input
Data format: ASCII
Maximum number of data sets that the internal memory can hold: 50

TLOG data (only on models with the computation function):

Trigger: Timeout of the timer
Data format: Binary
Maximum number of data sets that the internal memory can
hold: 400 (or within 16 files)

Report data (only on models with the computation function):

Type: Hourly, daily, hourly + daily, daily + weekly, daily + monthly
Data format: ASCII
Maximum number of data sets that the internal memory can hold: 40

Trigger function:

Event data file: Select the mode from FREE, TRIG, and ROTATE
Display data file + event data file: Select the mode from TRIG

and ROTATE

Display copy function:

Copy method: Key operation, communication command, or

remote input

Data format: PNG
Destination:

External storage medium or communication output

14.5 Storage Function