The CX2000 consists of a control function and a measurement function. The control
function executes control through PID control and ON/OFF control. The measurement
function displays and acquires measured data and control-output data.
Control Function
The CX2000 supports thee control modes: single-loop control, cascade control, and loop
control with PV switching or analog Retransmission. It can handle up to six loops of PID
control. In addition, the UT Series controllers made by Yokogawa M&C Corporation can
be connected and controlled simultaneously as external loops (16 loops max.). You can
check the control status on the controller style and faceplate style displays and the
hybrid style display that is a mixture of the two styles. Furthermore, the overview display
allows monitoring of all control loops including external loops. In addition, the CX2000
provides auto-tuning of PID constants as well as manual tuning, which enables you to
adjust the control parameters such as PID constants while checking the control status.
Measurement Function
In addition to the measured data for the control function, the CX2000 can acquire up to
20 channels of measured data. The data can be displayed as waveforms, numeric
values, and bar graphs. The measured data along with the control data can be stored to
a floppy disk, Zip disk, or ATA flash memory card using the built-in drive.
Conceptual Input/Output Diagram

Control input terminal

block 1

Control loop section

Up to 6 loops

(select 0, 2, 4, or 6 loops)

Measurement input

section

(10CH/20CH)

Ethernet

Controllers (up to 16 loops)

10 universal measurement inputs

100 VAC to 240 VAC or
24VDC/AC (P1 option)

SSR

• Universal control output: for 2 loops
Select current, voltage pulse, or relay
output.

LAN (Ethernet)

R3

R2

R1

Power

Supply

10 universal measurement inputs

10 universal measurement inputs

Option input/output

section

Select one from the following option terminal blocks.

Measurement alarm output +

remote input/output

(/A6R option)

Four 24-VDC transmitter

power supplies

(/TPS4 option)

Control DIO expansion

(/CST1 option)

PLC

(such as the FA-M3

by YOKOGAWA)

PC

Controls and

switches

CX2000

Measurement alarm output +

FAIL/memory end output

(/A4F option)

Measurement alarm output +

FAIL/memory end output +

remote input/output

(/A4FR option)

• Control contact input: 6 inputs

• Control contact input
Relay output: 2 outputs
Transistor output: 4 outputs

Magnet

switch

Contact
input
6 inputs

Contact
output
6 outputs

Control output terminal
block 1 (Loops 1 and 2)

Control output terminal
block 2 (Loops 3 and 4)

Control output terminal
block 3 (Loops 5 and 6)

Magnet

switch

Contact
input
6 inputs

Contact
output
6 outputs

Contact
input
6 inputs

Contact
output
6 outputs

Serial interface port

RS-422/485/232

Measurement input

terminal block 1

CH1 to CH10

Measurement input

terminal block 2

CH11 to CH20

Measurement alarm output

(/A6 option)

Chapter 1 Explanation of Functions

Advertising